3D Engineering View & Airflow Vector
LAM-100-HEPA
H13-H14
100% Leak Tested
DIN 53438-F1 Fire Proof
R0 Fiber Migration
Laminar Flow Absolute Filters 100 Panel (H13-H14)
High efficiency H13-H14 absolute HEPA panel filter with 100 mm core depth and factory leak scan certification.
Standard Efficiency
Air Inlet
Max Operating Temp
80°C
Rec. Final ΔP
600 Pa
SKU Variants
8 Standard Sizes
Technical Specification Summary (L-Diagram Metrics)
Compliant with ISO 16890, EN 779:2012 & EN 1822
Filter Class
H13-H14
Filter Media
Glass Fiber (Hot Melt)
Depth / Dimensions
150 mm
Rec. Final ΔP
600 Pa
Max Operating Temp
80°C
Frame / Header Material
Metallic (Extruded Aluminium)
Filtration Stage
3
Separator / Arrestance
Hot Melt
Gasket / Efficiency
Air Inlet
Product Technical Data Tabs
Engineering Overview & Functional Architecture
Laminar Flow HEPA panel filters designed for absolute air filtration in controlled contamination environments. Panels allow air to pass through micro-fine glass fibers that trap impurities down to MPPS. Suitable for pharmaceutical cleanrooms, neonatal incubators, and sterile operating theatres.
Verified Standards & Compliance Certifications
- DIN 53438-F1: Self-extinguishing fire-retardant media classification.
- UL Class 1 / UL 900: Underwriters Laboratories smoke and flammability compliance.
- R0 Particle Migration Rating: 100% paint defect prevention without lint shedding in down-draft spray booths.
- High Burst Pressure Resistance: Structural integrity verified up to > 6000 Pa burst pressure differential.
Technical Parameters & Operating Limits
| Parameter | Verified Value / Standard |
|---|---|
| Filter Classes | H13 (≥99.95%) / H14 (≥99.995%) |
| Panel Depth | 100 mm |
| Frame Depth | 150 mm |
| Recommended Cross Speed | 1.5 m/s |
| SKU Code | Dimensions W×L×D (mm) | Filter Class | Airflow (m³/h) | Initial ΔP (Pa) | Rec. Final ΔP (Pa) | Area (m²) | Action |
|---|---|---|---|---|---|---|---|
LAM-100-H13-305-305
|
305*305*150 (H13) | H13 | 150 | 80 | 600 | 4.5 | |
LAM-100-H13-305-610
|
305*610*150 (H13) | H13 | 300 | 80 | 600 | 9.0 | |
LAM-100-H13-610-610
|
610*610*150 (H13) | H13 | 600 | 80 | 600 | 18.0 | |
LAM-100-H13-610-1220
|
610*1220*150 (H13) | H13 | 1200 | 80 | 600 | 36.0 | |
LAM-100-H14-305-305
|
305*305*150 (H14) | H14 | 150 | 90 | 600 | 4.5 | |
LAM-100-H14-305-610
|
305*610*150 (H14) | H14 | 300 | 90 | 600 | 9.0 | |
LAM-100-H14-610-610
|
610*610*150 (H14) | H14 | 600 | 90 | 600 | 18.0 | |
LAM-100-H14-610-1220
|
610*1220*150 (H14) | H14 | 1200 | 90 | 600 | 36.0 |
Engineered Advantages & Performance Benefits
EN 1822 Leak Tested
Pressure Drop Curve (ΔP vs. Face Velocity / Air Volume)
Interactive laboratory curve. Hover over data points to inspect exact aerodynamic resistance values.
Target Industries & Deployment Sectors
Cleanroom Ceilings
Frequently Asked Technical Questions
Expert answers regarding installation, operating pressure limits, and nanofiber customization.
Direct Technical Inquiry & RFQ
Inquire Technical Specs & Pricing for LAM-100-HEPA
Our senior filtration and electrospinning engineers will review your operating parameters and reply with a formal quotation within 24 hours.