Mission-Critical Industrial Filtration & Nanofiber Engineering

Oil, Gas & Petrochemical Filtration

Gas turbine air intake filters, hydrocarbon mist coalescence, refinery amine loop filters, and explosion-proof ATEX rated assemblies.

5 Application Areas
100% Linked Solutions
ISO 16890 & EN 1822 Tested
DIN 53438 F1 Fire-Class Rated

Engineering Overview & Domain Challenges

Offshore platforms, natural gas processing facilities, and petrochemical refineries subject air filtration systems to severe operational stressors: high humidity, airborne salt aerosols, sulfur compounds, and violent pulse-jet cleaning. Our heavy-duty rigid pocket, mini-pleated, and V-cell filter banks prevent compressor blade fouling, turbine corrosion, and catalyst bed contamination.

✓ Targeted Sub-Micron Particulate Capture
✓ Continuous Fan Energy Savings & Low ΔP
✓ Certified Extended Service Life

Top 5 Application Areas & Certified Filtration Solutions

01

Gas Turbine Compressor Inlet Air Filtration

Heavy-duty industrial gas turbines consume thousands of cubic meters of air per minute. Sub-micron salt and sand particles cause compressor fouling, heat degradation, and catastrophic blade erosion.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Rigid Pocket Filters PPL & PFL (G4 / M5 Aerodynamic)
Stage 2 pre-filtration withstanding high humidity and turbulent inlet gusts
Aerodynamic injected PU header with burst pressure >6000 Pa; holds over 3900 g synthetic dust.
02

Offshore Platform Salt Spray & Marine Fog Separation

Marine environments carry deliquescent sea salt particles that liquefy under high relative humidity, penetrating conventional filters and corroding turbine hot sections.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
V-Cell Filters (M6–F9) with Hydrophobic Wet-Laid Media
High velocity marine air coalescing and sub-micron dry salt particulate filtration
Certified to ISO 16890 ePM1 >80%; corrosion-proof plastic frame with seamless polyurethane seal.
03

Refinery Amine Sweetening & Glycol Dehydration Loops

Iron sulfide scale and hydrocarbon condensates foul amine contactor trays, causing severe foaming, operational upsets, and off-spec treated gas.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Fine Series Pocket Filters & Aluminium Separators
Air intake protection for sulfur recovery units (SRU) and amine circulation compressors
Withstands exposure to acid gases (H2S and SO2); high mechanical stability up to 250°C.
04

Control Room Pressurization & Chemical Odor Scrubbing

Distributed control systems (DCS) in refineries suffer electronic card corrosion from trace chlorine and hydrogen sulfide fumes if positive air pressure is lost.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Sample 05 Activated Carbon Nanofiber Media + V-Cell HEPA
Creating ISA-71.04 Class G1 mild environment in control rooms
Zero sulfur dioxide breakthrough; provides clean particulate-free air satisfying DCS warranties.
05

Petrochemical Polyethylene / Polypropylene Powder Drying

Fluidized bed polymer drying loops require ultra-clean hot air where any ambient soot grain ruins polymer granule transparency and grade value.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Turbulent Flow Absolute HEPA Filters (H13 150/292 mm)
Absolute particulate removal in high volume hot drying air circuits up to 80°C
≥99.95% efficiency @ MPPS; wooden or galvanized steel frame rated for heavy continuous airflow.

Technical Standards & Laboratory Verification

All commercial filter models and electrospun nanofiber media comply with international air cleanliness and efficiency standards:

ISO 16890: Fractional efficiency testing against PM1, PM2.5, and PM10 particles.
EN 1822 / ISO 29463: Individual oil-thread & optical scanning at Most Penetrating Particle Size (MPPS).
DIN 53438-F1: Self-extinguishing flammability certification for industrial heating & paint curing ovens.
DIN CERTCO R0: Zero particulate migration (>10 µm) validation for automotive finishing lines.
INTERNATIONAL CLASSIFICATION STANDARDS

Air Filtration & Suspended Matter Standards Matrix

Comprehensive cross-reference comparing legacy EN 779:2012, ASHRAE 52.2, modern ISO 16890 fractional PM ratings, and high-efficiency cleanroom HEPA/ULPA EN 1822 standards.

Group EN 779:2012 ASHRAE 52.2 Arrestance (Am %) Efficiency (Em %) Min. Eff. 0.4µm ISO 16890 ePM1 ISO 16890 ePM2.5 ISO 16890 ePM10 ISO Coarse Final ΔP (Pa)
COARSE G1 MERV 1 50 ≤ Am < 65 — — — — — — 250 Pa
COARSE G2 MERV 2-4 65 ≤ Am < 80 — — — — — > 30% 250 Pa
COARSE G3 MERV 5-6 80 ≤ Am < 90 — — — — — > 40% 250 Pa
COARSE G4 MERV 7-8 90 ≤ Am — — — — — > 60% 250 Pa
MEDIUM M5 MERV 9-10 — 40 ≤ Em < 60 — — — > 50% — 450 Pa
MEDIUM M6 MERV 11-12 — 60 ≤ Em < 80 — — 50-65% > 60% — 450 Pa
FINE F7 MERV 13 — 80 ≤ Em < 90 35% 50-65% 65-80% > 85% — 450 Pa
FINE F8 MERV 14 — 90 ≤ Em < 95 55% 65-80% > 80% > 90% — 450 Pa
FINE F9 MERV 15 — 95 ≤ Em 70% > 80% > 95% > 95% — 450 Pa

* Note: Since 2018, ISO 16890 fully supersedes EN 779:2012. Discharge treatment using IPA vapor is mandatory to evaluate uncharged electrostatic media.