Engineering Overview & Domain Challenges
Thermal power plants, combined-cycle gas turbine (CCGT) stations, and integrated steelworks operate continuously under extreme atmospheric particulate burdens. Mill scale, coke dust, ambient desert silica, and cooling tower drift cause compressor erosion and heat-rate degradation. Our rugged multi-stage filtration solutions maintain MW output and avoid costly unscheduled plant shutdowns.
✓
Targeted Sub-Micron Particulate Capture
✓
Continuous Fan Energy Savings & Low ΔP
✓
Certified Extended Service Life
Engineered Matrices
Top 5 Application Areas & Certified Filtration Solutions
Siemens V94.2 and GE Frame 9 gas turbines installed across Iran's desert power stations face massive seasonal sandstorms that quickly clog standard panel filters.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Rigid Pocket Filters PPL (G4) + Pleated Heavy Pre-Filters
|
Stage 1 and 2 air intake protection capturing high dust mass with low energy drop |
✓
Aerodynamic pocket design eliminates vibration fatigue; DHC >3900 g synthetic dust per 595x595 mm cell.
|
Axial and centrifugal blast furnace blowers supply hot blast stoves with thousands of cubic meters of air, where graphite and coke dust cause impeller erosion.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Washable Metallic Panel Filters + V-Cell Compact Filters (F8)
|
High airflow dust separation protecting multi-megawatt axial blower impellers |
✓
Washable metal pre-filter reduces consumable operating costs; V-cell stage ensures ISO ePM1 >75%.
|
Power plant operators seeking to eliminate online and offline compressor water washes by upgrading final filter stages to E10–E12 EPA ratings.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
High Capacity V-Type HEPA Filters (E10–E12)
|
Terminal turbine intake filtration achieving zero sub-micron fouling on compressor blades |
✓
Eliminates compressor degradation; maintains constant power output and avoids 3–5% heat rate loss.
|
High-voltage switchgear rooms located near hot rolling stands are exposed to conductive iron oxide scale dust that causes catastrophic electrical arcing.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Fine Pocket Filters F7/F8 with Galvanized Steel Frames
|
Pressurization filtration ensuring zero conductive metallic particulate ingress into electrical rooms |
✓
Meets NFPA and electrical substation cleanliness standards; flame resistant media prevents fire spread.
|
Self-cleaning pulse-jet filter houses in desert environments require cartridge media that releases cake during pulsing without embedding sub-micron dust.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Sample 04 Nanofiber-Coated Cartridge Media (SRV-02)
|
Surface filtration preventing deep bed clogging and reducing compressed air pulse frequency |
✓
Increases pulse cleaning recovery efficiency by 70%; extends cartridge service life beyond 16,000 hours.
|
Compliance & Verification
Technical Standards & Laboratory Verification
All commercial filter models and electrospun nanofiber media comply with international air cleanliness and efficiency standards:
ISO 16890: Fractional efficiency testing against PM1, PM2.5, and PM10 particles.
EN 1822 / ISO 29463: Individual oil-thread & optical scanning at Most Penetrating Particle Size (MPPS).
DIN 53438-F1: Self-extinguishing flammability certification for industrial heating & paint curing ovens.
DIN CERTCO R0: Zero particulate migration (>10 µm) validation for automotive finishing lines.