Engineering Overview & Domain Challenges
Offshore platforms, natural gas processing facilities, and petrochemical refineries subject air filtration systems to severe operational stressors: high humidity, airborne salt aerosols, sulfur compounds, and violent pulse-jet cleaning. Our heavy-duty rigid pocket, mini-pleated, and V-cell filter banks prevent compressor blade fouling, turbine corrosion, and catalyst bed contamination.
✓
Targeted Sub-Micron Particulate Capture
✓
Continuous Fan Energy Savings & Low ΔP
✓
Certified Extended Service Life
Engineered Matrices
Top 5 Application Areas & Certified Filtration Solutions
Heavy-duty industrial gas turbines consume thousands of cubic meters of air per minute. Sub-micron salt and sand particles cause compressor fouling, heat degradation, and catastrophic blade erosion.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Rigid Pocket Filters PPL & PFL (G4 / M5 Aerodynamic)
|
Stage 2 pre-filtration withstanding high humidity and turbulent inlet gusts |
✓
Aerodynamic injected PU header with burst pressure >6000 Pa; holds over 3900 g synthetic dust.
|
Marine environments carry deliquescent sea salt particles that liquefy under high relative humidity, penetrating conventional filters and corroding turbine hot sections.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
V-Cell Filters (M6–F9) with Hydrophobic Wet-Laid Media
|
High velocity marine air coalescing and sub-micron dry salt particulate filtration |
✓
Certified to ISO 16890 ePM1 >80%; corrosion-proof plastic frame with seamless polyurethane seal.
|
Iron sulfide scale and hydrocarbon condensates foul amine contactor trays, causing severe foaming, operational upsets, and off-spec treated gas.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Fine Series Pocket Filters & Aluminium Separators
|
Air intake protection for sulfur recovery units (SRU) and amine circulation compressors |
✓
Withstands exposure to acid gases (H2S and SO2); high mechanical stability up to 250°C.
|
Distributed control systems (DCS) in refineries suffer electronic card corrosion from trace chlorine and hydrogen sulfide fumes if positive air pressure is lost.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Sample 05 Activated Carbon Nanofiber Media + V-Cell HEPA
|
Creating ISA-71.04 Class G1 mild environment in control rooms |
✓
Zero sulfur dioxide breakthrough; provides clean particulate-free air satisfying DCS warranties.
|
Fluidized bed polymer drying loops require ultra-clean hot air where any ambient soot grain ruins polymer granule transparency and grade value.
|
Recommended Nanofiber / Filter Solution |
Engineering Purpose |
Operational & Performance Benefits |
|
Turbulent Flow Absolute HEPA Filters (H13 150/292 mm)
|
Absolute particulate removal in high volume hot drying air circuits up to 80°C |
✓
≥99.95% efficiency @ MPPS; wooden or galvanized steel frame rated for heavy continuous airflow.
|
Compliance & Verification
Technical Standards & Laboratory Verification
All commercial filter models and electrospun nanofiber media comply with international air cleanliness and efficiency standards:
ISO 16890: Fractional efficiency testing against PM1, PM2.5, and PM10 particles.
EN 1822 / ISO 29463: Individual oil-thread & optical scanning at Most Penetrating Particle Size (MPPS).
DIN 53438-F1: Self-extinguishing flammability certification for industrial heating & paint curing ovens.
DIN CERTCO R0: Zero particulate migration (>10 µm) validation for automotive finishing lines.