Mission-Critical Industrial Filtration & Nanofiber Engineering

Medical, Pharmaceutical & Wound Care

Controlled-release wound care matrices, active pharmaceutical delivery veils, and hospital cleanroom aseptic boundary materials.

5 Application Areas
100% Linked Solutions
ISO 16890 & EN 1822 Tested
DIN 53438 F1 Fire-Class Rated

Engineering Overview & Domain Challenges

Biomedical materials require precise control over fiber morphology, biocompatibility, porosity, and drug-loading capacity. Nano Sazeh Aryan Nik Co. develops specialized electrospun matrices tailored for wound care, tissue scaffolding, and transdermal drug delivery. In collaboration with partners like Kimia Zist Tarmim Co., our technology platform delivers next-generation bio-functional dressing structures.

✓ Targeted Sub-Micron Particulate Capture
✓ Continuous Fan Energy Savings & Low ΔP
✓ Certified Extended Service Life

Top 5 Application Areas & Certified Filtration Solutions

01

Advanced Nanofibrous Wound Dressings (Kimia Zist Tarmim Collaboration)

Chronic diabetic foot ulcers, severe pressure sores, and second-degree burns demand dressings that mimic the natural cellular matrix while delivering local therapeutic agents.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Sample 02 Nanofibrous Wound Dressing (Controlled Release)
High-surface-area fibrous dressing matrix loaded with active therapeutic agents
Accelerates granulation tissue formation; prevents secondary trauma during dressing changes.
02

Aseptic Pharmaceutical Cleanrooms (ISO Class 5 / Grade A)

Injectable biologic manufacturing facilities require terminal filtration that guarantees zero microbial colony-forming units (CFU) in sterile filling zones.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Laminar Flow Absolute Filters 48 & 75 (H14 / U15)
Terminal laminar ceiling filtration over sterile filling needles and lyophilizers
Guaranteed ≥99.995% MPPS efficiency; individually leak-scanned with documented test certificates.
03

Surgical Masks, Respirator Veils & Bio-Barrier Membranes

Medical staff require respirators with high bacterial filtration efficiency (BFE >99%) that remain breathable during long operating shifts.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Electrospun Nanofiber Veil on Spunbond Polypropylene (SRV-01)
Mechanical particulate and virus interception layer replacing electrostatic meltblown
Maintains efficiency in humid breath conditions without losing electrostatic charge; ΔP <30 Pa.
04

Active Drug Delivery Patches & Transdermal Platforms

Transdermal therapeutic systems require uniform matrix porosity and zero solvent residues to ensure predictable systemic drug absorption.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Sample 03 Nanofibrous Delivery Matrix
Formulation development for transdermal drug delivery and localized skin release
High drug loading capacity up to 30 wt%; programmable zero-order or Fickian release profiles.
05

Exudate Management & Hemostatic Sponges

Trauma surgery and emergency care require rapid clotting agents anchored in porous fibrous foams to halt arterial or venous hemorrhage.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Biomedical Reticulated Foam Coated with Bioactive Nanofibers
High volumetric blood absorption and rapid fibrin clotting cascade initiation
Absorbs over 30× its dry weight in fluids; bioactive veil promotes instant platelet aggregation.

Technical Standards & Laboratory Verification

All commercial filter models and electrospun nanofiber media comply with international air cleanliness and efficiency standards:

ISO 16890: Fractional efficiency testing against PM1, PM2.5, and PM10 particles.
EN 1822 / ISO 29463: Individual oil-thread & optical scanning at Most Penetrating Particle Size (MPPS).
DIN 53438-F1: Self-extinguishing flammability certification for industrial heating & paint curing ovens.
DIN CERTCO R0: Zero particulate migration (>10 µm) validation for automotive finishing lines.
INTERNATIONAL CLASSIFICATION STANDARDS

Air Filtration & Suspended Matter Standards Matrix

Comprehensive cross-reference comparing legacy EN 779:2012, ASHRAE 52.2, modern ISO 16890 fractional PM ratings, and high-efficiency cleanroom HEPA/ULPA EN 1822 standards.

Group EN 779:2012 ASHRAE 52.2 Arrestance (Am %) Efficiency (Em %) Min. Eff. 0.4µm ISO 16890 ePM1 ISO 16890 ePM2.5 ISO 16890 ePM10 ISO Coarse Final ΔP (Pa)
COARSE G1 MERV 1 50 ≤ Am < 65 — — — — — — 250 Pa
COARSE G2 MERV 2-4 65 ≤ Am < 80 — — — — — > 30% 250 Pa
COARSE G3 MERV 5-6 80 ≤ Am < 90 — — — — — > 40% 250 Pa
COARSE G4 MERV 7-8 90 ≤ Am — — — — — > 60% 250 Pa
MEDIUM M5 MERV 9-10 — 40 ≤ Em < 60 — — — > 50% — 450 Pa
MEDIUM M6 MERV 11-12 — 60 ≤ Em < 80 — — 50-65% > 60% — 450 Pa
FINE F7 MERV 13 — 80 ≤ Em < 90 35% 50-65% 65-80% > 85% — 450 Pa
FINE F8 MERV 14 — 90 ≤ Em < 95 55% 65-80% > 80% > 90% — 450 Pa
FINE F9 MERV 15 — 95 ≤ Em 70% > 80% > 95% > 95% — 450 Pa

* Note: Since 2018, ISO 16890 fully supersedes EN 779:2012. Discharge treatment using IPA vapor is mandatory to evaluate uncharged electrostatic media.