Mission-Critical Industrial Filtration & Nanofiber Engineering

HVAC, Cleanroom & Air Purification

Aseptic pharmaceutical cleanrooms, hospital operating suites, semiconductor fabrication bays, and high-efficiency central air handling units.

5 Application Areas
100% Linked Solutions
ISO 16890 & EN 1822 Tested
DIN 53438 F1 Fire-Class Rated

Engineering Overview & Domain Challenges

Aseptic environments and high-efficiency commercial buildings require multi-stage air filtration trains that guarantee zero particle migration, strict laminar velocity distributions, and absolute microbial exclusion. From initial intake pre-filters to ceiling HEPA/ULPA terminal hoods, our verified configurations satisfy ISO 14644-1 cleanliness classes from ISO Class 1 to ISO Class 8.

✓ Targeted Sub-Micron Particulate Capture
✓ Continuous Fan Energy Savings & Low ΔP
✓ Certified Extended Service Life

Top 5 Application Areas & Certified Filtration Solutions

01

Pharmaceutical Aseptic Suites & ISO Class 5 Fill-Finish Areas

Terminal ceiling diffusers in vial-filling suites require ultra-low penetration air filters operating at uniform face velocities (0.45 m/s ± 20%) to prevent turbulence.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Laminar Flow Absolute Filters 48 & 65 Depth (H14)
Terminal laminar ceiling filtration achieving ≥99.995% MPPS efficiency
Individually scanned and certified to EN 1822; extruded anodized aluminum profile with faceguard on clean side.
02

Hospital Operating Theatres & Isolation Wards

Surgical operating suites require high volume air exchange with positive differential pressure to sweep airborne pathogens away from the patient surgical field.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
High Capacity V-Type HEPA Filters & Laminar 100 (H13-H14)
Central AHU terminal protection handling up to 4000 m³/h per cell
Large media area up to 40 m² per cell ensures extended life and low fan energy consumption (initial ΔP <250 Pa).
03

Central Commercial AHU Multi-Stage Filtration Trains

Commercial towers, airports, and universities require balanced pre-filtration to protect secondary fine filters from rapid dust loading and coil fouling.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Pleated G4 Pre-Filters + Fine Pocket Filters M6/F7
Staged particle removal from coarse pollen (G4) to respirable PM2.5 (F7)
Aerodynamic pocket design ensures uniform inflation without pocket bunching; certified to ISO 16890.
04

Kitchen Exhaust, Grease Mist & Odor Removal Systems

Food processing plants, hotel kitchens, and restaurants face stringent municipal odor and grease duct-fire prevention regulations.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Sample 05 Nanofibrous Hood Media with Activated Carbon
Simultaneous sub-micron grease smoke interception and VOC cooking odor adsorption
Replaces heavy carbon bed canisters; easily integrated into standard baffle filter tracks.
05

Acoustic Attenuation & Low-Resistance Return Air Pads

Air recirculation systems in recording studios, lecture theaters, and office plenum boxes need filtration without acoustic fan rumble.

Recommended Nanofiber / Filter Solution Engineering Purpose Operational & Performance Benefits
Reticulated Foam Nanofiber Veil Media Pads
Low-noise particulate filtration in return air grilles and fan-coil units
Initial pressure drop under 25 Pa @ 1.5 m/s; open-cell structure absorbs sound vibrations.

Technical Standards & Laboratory Verification

All commercial filter models and electrospun nanofiber media comply with international air cleanliness and efficiency standards:

ISO 16890: Fractional efficiency testing against PM1, PM2.5, and PM10 particles.
EN 1822 / ISO 29463: Individual oil-thread & optical scanning at Most Penetrating Particle Size (MPPS).
DIN 53438-F1: Self-extinguishing flammability certification for industrial heating & paint curing ovens.
DIN CERTCO R0: Zero particulate migration (>10 µm) validation for automotive finishing lines.
INTERNATIONAL CLASSIFICATION STANDARDS

Air Filtration & Suspended Matter Standards Matrix

Comprehensive cross-reference comparing legacy EN 779:2012, ASHRAE 52.2, modern ISO 16890 fractional PM ratings, and high-efficiency cleanroom HEPA/ULPA EN 1822 standards.

Group EN 779:2012 ASHRAE 52.2 Arrestance (Am %) Efficiency (Em %) Min. Eff. 0.4µm ISO 16890 ePM1 ISO 16890 ePM2.5 ISO 16890 ePM10 ISO Coarse Final ΔP (Pa)
COARSE G1 MERV 1 50 ≤ Am < 65 — — — — — — 250 Pa
COARSE G2 MERV 2-4 65 ≤ Am < 80 — — — — — > 30% 250 Pa
COARSE G3 MERV 5-6 80 ≤ Am < 90 — — — — — > 40% 250 Pa
COARSE G4 MERV 7-8 90 ≤ Am — — — — — > 60% 250 Pa
MEDIUM M5 MERV 9-10 — 40 ≤ Em < 60 — — — > 50% — 450 Pa
MEDIUM M6 MERV 11-12 — 60 ≤ Em < 80 — — 50-65% > 60% — 450 Pa
FINE F7 MERV 13 — 80 ≤ Em < 90 35% 50-65% 65-80% > 85% — 450 Pa
FINE F8 MERV 14 — 90 ≤ Em < 95 55% 65-80% > 80% > 90% — 450 Pa
FINE F9 MERV 15 — 95 ≤ Em 70% > 80% > 95% > 95% — 450 Pa

* Note: Since 2018, ISO 16890 fully supersedes EN 779:2012. Discharge treatment using IPA vapor is mandatory to evaluate uncharged electrostatic media.